AC Infinity Controller 69 Pro Setup
Posted · 18:01 · Watch on YouTube
Full setup walkthrough for the 69 Pro: programming schedules, sensor calibration, fan curves.
Chapters
Notes from the video
- Grow light: set the off level to 0. Anything higher and the light stays on at that level when the schedule turns it off.
- Grow light: the on level depends on your stage and how far the light hangs from the plants. Level 4 is used in the video. Run it in Schedule mode.
- Exhaust fan: off level 0, on level 6, in Auto mode with triggers at 80°F and 60% humidity. It runs until the tent drops back under both.
- Circulating fan: the same 80°F and 60% triggers, but an off level of 1 or 2 so the air in the tent never goes still.
- Dehumidifier: runs through a UIS control plug, which only switches power on and off like a smart plug. Auto trigger at 65% humidity. Use one trigger at a time.
- Sunrise and sunset: a 2 hour setting ramps the light up to its level over 2 hours, and down again before lights off.
- Transition buffers of 1 or 2 degrees stop a device from switching on and off when the tent sits right at the trigger.
10% Off Store-Wide
Get My CodeAffiliate link. 218 Cultivation may earn a commission at no extra cost to you. Details.
Go deeper
More AC Infinity videos
AC Infinity Controller AI+22:15
AC Infinity Propagation Tent Review8:11
AC Infinity Soil Sensor: Real-World Test9:48
AC Infinity HYDRONE 7 Hands-On Review13:57
How to Automate CO2 in Your Grow Tent11:32